Multi
Mobile Homepage logo

Service & Repair of Ando AQ6317C Optical Spectrum Analyzer OSA



Expert Technicians



Original Parts



Fast Turn-Arounds



Maintenance Plans

Premier Repair Services for ANDO AQ6317C Optical Spectrum Analyzer

At Wyoming Electronics Inc., we understand the critical role that an optical spectrum analyzer plays in your operations, which is why we offer specialized repair services for the ANDO AQ6317C. Our experienced technicians are equipped with the knowledge and tools to address a wide range of issues, ensuring your equipment functions at its best.

Full Spectrum Repair Services for ANDO AQ6317C

The ANDO AQ6317C is a highly sophisticated instrument known for its reliability and precision in optical spectrum analysis. However, regular use and complex operational demands can lead to technical issues. We offer comprehensive diagnostics and repair services tailored to address common and complex problems:

Key Service Areas Include:

  • Startup and Initialization Issues:
    • System Stuck on Initializing: We resolve problems where the AQ6317C is stuck on initializing at step 8/8, ensuring a smooth and complete startup.
    • Boot Failures: We troubleshoot devices that fail to boot, addressing potential software or hardware malfunctions.
  • Display and Visual Output Problems:
    • Display Issues: If your AQ6317C has no display output while external monitors work, we diagnose and repair internal display components or connectivity issues.
  • Optical Signal Detection:
    • No Optical Signal: We fix issues preventing the analyzer from detecting optical signals, essential for accurate spectrum analysis.
  • Operational Control Concerns:
    • Stuck or Broken Power Button: We provide quick repairs or replacements for malfunctioning power buttons to ensure reliable operation.
  • Calibration and Alignment:
    • Calibration Failures: Both internal and external wavelength calibrations are meticulously addressed to meet specified accuracy standards.
    • Optical Alignment Issues: We correct failures in internal optical alignment that impact the accuracy and reliability of measurements.
  • Component-Specific Errors:
    • Monochromator Errors: We conduct detailed repairs to resolve errors associated with the monochromator, crucial for accurate wavelength selection and analysis.
    • Low Optical Power Readings: Adjustments or repairs are made to the power measurement system to correct abnormally low readings, ensuring precise data.

Why Choose Wyoming Electronics Inc. for Your ANDO AQ6317C Repairs?

  • Expert Technicians: Our team consists of highly skilled professionals with extensive experience in servicing ANDO spectrum analyzers.
  • Advanced Diagnostic Tools: Utilizing the latest in diagnostic technologies, we quickly identify and resolve issues, reducing downtime and ensuring effective repairs.
  • Genuine Replacement Parts: We use only authentic, manufacturer-approved parts for all repairs, maintaining the integrity and performance of your AQ6317C.

Steps to getting your AQ6317C fixed:
1) Fill our RMA form here, and ship us your defective AQ6317C
2) We will perform free evaluation and quote you with lead time
3) You will accept or decline the repair
4) We will repair and or return your AQ6317C

 

Applicable fibers

  • SMF, GI (50/125 µm)

Measurement wavelength range

  • 600 to 1750 nm

Wavelength accuracy

  • ±0.02 nm (1520 to 1580 nm, after calibration with build-in reference light source)
  • ±0.04 nm (1580 to 1620 nm, after calibration with build-in reference light source)
  • ±0.3 nm (600 to 1750 nm)

Wavelength linearity

  • ±0.01 nm (1520 to 1580 nm)
  • ±0.02 nm (1580 to 1620 nm)

Wavelength repeatability

  • ±0.003 nm (1 min)

Wavelength resolution

  • Max. resolution: 0.015 nm or better (1520 to 1620 nm, resolution setting: 0.01 nm)
  • 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1.0, 2.0 nm

Resolution accuracy

  • ±5 % (1300 to 1650 nm, resolution: 0.05 nm or more, resolution correction: OFF)

Measurement level range

  • -90 to +20 dBm (1200 to 1650 nm, sensitivity: HIGH3)
  • +80 to +20 dBm (600 to 1200 nm, sensitivity: HIGH3)
  • -60 to +20 dBm (600 to 1000 nm, sensitivity: HIGH3)

Level accuracy

  • ±0.3 dB (1310/1550 nm, input: -30 dBm, sensitivity: HIGH3-1)

Level linearity

  • ±0.05 dB (input: -10 to 30 dBm, sensitivity: HIGH3-1)

Level flatness

  • ±0.1 dB (1520 to 1580 nm), ±0.2 dB (1580 to 1620 nm)

Polarization dependency

  • ±0.05 dB (1550/1600 nm), ±0.05 dB (typ. 1310 nm)

Dynamic range

  • 80 dB (1523 nm, peak ±0.4 nm, resolution: 0.01 nm)
  • 70 dB (1523 nm, peak ±0.4 nm, resolution: 0.1 nm)
  • 45 dB (1523 nm, ave.: 1 s, resolution: 0.1 nm)

Sweep time

  • Approx. 500 ms (Span: 100 nm or less, sensitivity: NORM, HOLD, ave.: 1, 501 samples or less, resolution correction: OFF)
  • Approx. 0.5 s (Span: 100 nm or less, sensitivity: HIGH2, ave.: 1, 501 samples, No signal)

Function

  • Program function (20 program, 200 steps)

Automatic measurement

  • Long-term measurement function

Setting of measuring conditions

  • Scan setting: 0 to 1200 nm
  • Measuring sensitivity setting: NORMAL HOLD/AUTO, MID, HIGH1/2/3
  • Number of averaging setting: 1 to 1000 times
  • Sample number setting: 11 to 20001, AUTO
  • Automatic setting function of measuring conditions
  • Sweep-between-marker function
  • 0 nm sweep function
  • Pulse light measurement function
  • Air/vacuum wavelength measurement function
  • TLS synchronized measurement function

Function

Trace display

  • Level scale setting: 0.1 to 10 dB/div, linear
  • Simultaneous display of 3 independent traces
  • Max./Min. hold display
  • Roll averaging display
  • Calculation-between-traces display
  • Normalized display
  • Curve-fit display
  • 3D display
  • Split display
  • Power density display, % display, dB/km display
  • Frequency display of horizontal axis scale

Data analysis

  • WDM waveform analysis (wavelength/level/SNR list display)
  • Optical fiber amplifier analysis (GAIN/NF, Single/Multi channel)
  • PMD analysis, Optical filter analysis, BFL-BLD analysis, FP-LD analysis, LED analysis, SMSR analysis
  • Peak search, bottom search, spectral width search, notch with search
  • Data marker (max. 200), line marker (analysis range specification)
  • Graph display of long-term measurement result

Others

  • Self-wavelength calibration function (using built-in reference light source)
  • Wavelength/Level compensation function, label function, help function

Memory

Built-in FDD

  • 3.5-inch 2HD

Internal memory

  • 32 traces, 20 programs

File format

  • Trace file, program file, measuring condition file, text file (trace, analysis data, etc.), graphics file (BMP,TIFF)

Data output

  • Built-in high speed printer

Interface

  • Remote control: GPIB (2 ports)
  • TLS control interfaces (TTL)
  • Sweep trigger input (TTL)
  • Sample enable input (TTL)
  • Sample trigger input (TTL)
  • Analog output (0 to 5 V)
  • Video output (VGA)

Display

  • 9.4-inch color LCD (Resolution: 640 x 480 dots)

Optical connector

  • FC (Standard)

Power requirement

  • AC 100 to 120/200 to 240 V, 50/60 Hz

Environmental conditions

  • Operating temperature: 5 to 40 °C
  • Storage temperature: -10 to +50 °C
  • Humidity: 80 %RH or less (no condensation)

Dimensions and mass

  • Approx. 425 (W) x 222 (H) x 450 (D) mm, approx. 30 kg

Notes:

  1. Horizontal scale: wavelength display mode
  2. Vertical scale: peak power display mode, resolution: 0.05 nm or more, resolution correction: OFF
  3. At 15 to 30 °C, with 10/125 µm single mode fiber, after 2 hours of warm-up, after optical alignment

Calibration Certificate included!

Get a Quote for Service


Call : 215-485-6313

sales@wyomingelectronics.net

Additional information

Brand

MPN

Wavelength Range

Absolute WL Accuracy

Wavelength Linearity

Power Level Accuracy

Product Type

Can’t find what you are looking for?