Expert Technicians
Original Parts
Fast Turn-Arounds
Maintenance Plans
Comprehensive Repair Services for ANDO AQ6317B Optical Spectrum Analyzer at Wyoming Electronics Inc.
At Wyoming Electronics Inc., we are dedicated to offering specialized repair services for the ANDO AQ6317B Optical Spectrum Analyzer, ensuring it operates at peak efficiency. Our highly trained technicians possess extensive experience in handling complex optical equipment, making us a trusted partner for maintaining your critical measurement tools.
Full Range of Diagnostic and Repair Services for ANDO AQ6317B:
Common Issues We Address:
- Startup and Initialization Challenges:
- Stuck on Initialization: If your AQ6317B is frozen during startup at step 8/8, we provide solutions to resolve these hang-ups, ensuring a smooth boot process.
- Booting Failures: We troubleshoot and repair issues preventing the device from turning on, including power supply failures and internal component malfunctions.
- Display and Visual Output Problems:
- Non-Functional Display: Our services include diagnosing and fixing display issues to restore clear and functional visual output for your operations.
- Signal Detection and Calibration:
- No Optical Signal Detection: We rectify problems where the device fails to detect optical signals, crucial for its primary function in spectrum analysis.
- Wavelength Calibration Issues: Both internal and external wavelength calibrations are addressed to ensure your analyzer meets all specified accuracy standards.
- Optical Alignment Complications: We correct any internal optical alignment failures that can significantly impact the accuracy and reliability of measurements.
- Component Specific Repairs:
- Stuck or Broken Power Button: Quick fixes or replacements are provided for malfunctioning power buttons to ensure consistent operability.
- Monochromator Errors: Detailed repairs are conducted to resolve errors related to the monochromator, essential for precise wavelength analysis.
- Low Optical Power Readings: Adjustments or repairs to the power measurement system are performed to correct low optical power readings, ensuring accurate and reliable data.
Why Trust Wyoming Electronics Inc. with Your AQ6317B Repair?
- Expert Technicians: Our team consists of professionals with specialized training in optical spectrum analyzers, particularly the ANDO series, ensuring that your equipment is handled with expertise.
- Advanced Diagnostic Equipment: We employ the latest technology in diagnostics to swiftly and accurately pinpoint issues, minimizing downtime and ensuring effective repairs.
- Quality Assurance: Only genuine, manufacturer-recommended parts are used for all repairs to maintain the integrity and performance of your AQ6317B.
- Transparent Pricing: We provide a clear and competitive pricing structure with a maximum service charge of $6500. However, precise quotes are provided post-evaluation, tailored to the specific repair needs of your equipment.
Steps to getting your AQ6317B fixed:
1) Fill our RMA form here, and ship us your defective AQ6317B
2) We will perform free evaluation and quote you with lead time
3) You will accept or decline the repair
4) We will repair and or return your AQ6317B
Applicable fibers
- SMF, GI (50/125 µm)
Measurement wavelength range
- 600 to 1750 nm
Wavelength accuracy
- ±0.02 nm (1520 to 1580 nm, after calibration with build-in reference light source)
- ±0.04 nm (1580 to 1620 nm, after calibration with build-in reference light source)
- ±0.3 nm (600 to 1750 nm)
Wavelength linearity
- ±0.01 nm (1520 to 1580 nm)
- ±0.02 nm (1580 to 1620 nm)
Wavelength repeatability
- ±0.003 nm (1 min)
Wavelength resolution
- Max. resolution: 0.015 nm or better (1520 to 1620 nm, resolution setting: 0.01 nm)
- 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1.0, 2.0 nm
Resolution accuracy
- ±5 % (1300 to 1650 nm, resolution: 0.05 nm or more, resolution correction: OFF)
Measurement level range
- -90 to +20 dBm (1200 to 1650 nm, sensitivity: HIGH3)
- +80 to +20 dBm (600 to 1200 nm, sensitivity: HIGH3)
- -60 to +20 dBm (600 to 1000 nm, sensitivity: HIGH3)
Level accuracy
- ±0.3 dB (1310/1550 nm, input: -30 dBm, sensitivity: HIGH3-1)
Level linearity
- ±0.05 dB (input: -10 to 30 dBm, sensitivity: HIGH3-1)
Level flatness
- ±0.1 dB (1520 to 1580 nm), ±0.2 dB (1580 to 1620 nm)
Polarization dependency
- ±0.05 dB (1550/1600 nm), ±0.05 dB (typ. 1310 nm)
Dynamic range
- 80 dB (1523 nm, peak ±0.4 nm, resolution: 0.01 nm)
- 70 dB (1523 nm, peak ±0.4 nm, resolution: 0.1 nm)
- 45 dB (1523 nm, ave.: 1 s, resolution: 0.1 nm)
Sweep time
- Approx. 500 ms (Span: 100 nm or less, sensitivity: NORM, HOLD, ave.: 1, 501 samples or less, resolution correction: OFF)
- Approx. 0.5 s (Span: 100 nm or less, sensitivity: HIGH2, ave.: 1, 501 samples, No signal)
Function
- Program function (20 program, 200 steps)
Automatic measurement
- Long-term measurement function
Setting of measuring conditions
- Scan setting: 0 to 1200 nm
- Measuring sensitivity setting: NORMAL HOLD/AUTO, MID, HIGH1/2/3
- Number of averaging setting: 1 to 1000 times
- Sample number setting: 11 to 20001, AUTO
- Automatic setting function of measuring conditions
- Sweep-between-marker function
- 0 nm sweep function
- Pulse light measurement function
- Air/vacuum wavelength measurement function
- TLS synchronized measurement function
Function
Trace display
- Level scale setting: 0.1 to 10 dB/div, linear
- Simultaneous display of 3 independent traces
- Max./Min. hold display
- Roll averaging display
- Calculation-between-traces display
- Normalized display
- Curve-fit display
- 3D display
- Split display
- Power density display, % display, dB/km display
- Frequency display of horizontal axis scale
Data analysis
- WDM waveform analysis (wavelength/level/SNR list display)
- Optical fiber amplifier analysis (GAIN/NF, Single/Multi channel)
- PMD analysis, Optical filter analysis, BFL-BLD analysis, FP-LD analysis, LED analysis, SMSR analysis
- Peak search, bottom search, spectral width search, notch with search
- Data marker (max. 200), line marker (analysis range specification)
- Graph display of long-term measurement result
Others
- Self-wavelength calibration function (using built-in reference light source)
- Wavelength/Level compensation function, label function, help function
Memory
Built-in FDD
- 3.5-inch 2HD
Internal memory
- 32 traces, 20 programs
File format
- Trace file, program file, measuring condition file, text file (trace, analysis data, etc.), graphics file (BMP,TIFF)
Data output
- Built-in high speed printer
Interface
- Remote control: GPIB (2 ports)
- TLS control interfaces (TTL)
- Sweep trigger input (TTL)
- Sample enable input (TTL)
- Sample trigger input (TTL)
- Analog output (0 to 5 V)
- Video output (VGA)
Display
- 9.4-inch color LCD (Resolution: 640 x 480 dots)
Optical connector
- FC (Standard)
Power requirement
- AC 100 to 120/200 to 240 V, 50/60 Hz
Environmental conditions
- Operating temperature: 5 to 40 °C
- Storage temperature: -10 to +50 °C
- Humidity: 80 %RH or less (no condensation)
Dimensions and mass
- Approx. 425 (W) x 222 (H) x 450 (D) mm, approx. 30 kg
Notes:
- Horizontal scale: wavelength display mode
- Vertical scale: peak power display mode, resolution: 0.05 nm or more, resolution correction: OFF
- At 15 to 30 °C, with 10/125 µm single mode fiber, after 2 hours of warm-up, after optical alignment
Calibration Certificate included!
Get a Quote for Service
Call : 215-485-6313
sales@wyomingelectronics.net
Additional information
Brand | |
---|---|
MPN | |
Absolute WL Accuracy | ±0.5nm, ±0.2nm (after user calibration over full wavelength range) |
Wavelength Repeatability | |
Wavelength Linearity | |
Power Level Accuracy | |
Product Type |