Specialized Repair Services for ANDO AQ6315E Optical Spectrum Analyzer

At Wyoming Electronics Inc., we provide top-tier repair services for the ANDO AQ6315E Optical Spectrum Analyzer, ensuring your specialized equipment functions seamlessly. Recognized for our expertise and quick service, we guarantee your optical spectrum analyzer is optimized for performance, offering extensive diagnostics and precise repairs.

Comprehensive Repair and Maintenance for ANDO AQ6315E:

The ANDO AQ6315E is a sophisticated instrument utilized in diverse applications requiring precise optical analysis. Despite its reliability, various technical issues can impact its performance. Our skilled technicians are equipped to address a wide range of these issues, employing the latest technology and genuine replacement parts.

Key Service Areas Include:

  • Startup and Operational Issues:
    • Initialization Problems: If your AQ6315E is stuck on step 8/8 during startup, we provide swift solutions to resolve these initialization hang-ups, ensuring a smooth start.
    • Boot Failures: We troubleshoot and repair conditions where the AQ6315E fails to boot, tackling both software and hardware malfunctions effectively.
  • Display and Visual Output Concerns:
    • Display Issues: For units with non-functioning displays, we diagnose and rectify display problems to restore clear and functional user interfaces.
  • Optical Signal and Calibration Challenges:
    • Signal Detection Failures: We correct problems that prevent the device from detecting optical signals, crucial for its operation in spectrum analysis.
    • Calibration Issues: Our service encompasses both internal and external wavelength calibration failures, ensuring the analyzer meets all specified accuracy standards.
    • Optical Alignment Errors: We address failures in internal optical alignment that could significantly impact measurement accuracy.
  • Component-Specific Repairs:
    • Power Button Malfunctions: We offer repair or replacement for stuck or broken power buttons, ensuring reliable operation.
    • Monochromator Errors: We resolve errors associated with the monochromator, essential for precise wavelength analysis.
    • Low Optical Power Readings: Adjustments or repairs are conducted to address inaccurately low optical power readings, ensuring precise data accuracy.

Why Choose Wyoming Electronics Inc. for Your AQ6315E Repairs?

  • Expertise: Our technicians possess extensive experience with optical spectrum analyzers, particularly the ANDO series, ensuring knowledgeable and accurate service.
  • Advanced Tools: We utilize state-of-the-art diagnostic and repair tools to identify and resolve issues efficiently, minimizing downtime and enhancing equipment reliability.
  • Quality Parts: Only manufacturer-approved parts are used in our repairs to maintain equipment integrity and performance.
  • Transparent Pricing: We offer a competitive and clear pricing model with a maximum service charge of $6500. Detailed quotes are provided after a thorough evaluation, tailored to the specific repair needs of your equipment.

Steps to getting your AQ6315E fixed:
1) Fill our RMA form here, and ship us your defective AQ6315E
2) We will perform free evaluation and quote you with lead time
3) You will accept or decline the repair
4) We will repair and or return your AQ6315E

 

Applicable fibers

  • SMF, GI (50/125 µm)

Measurement wavelength range

  • 600 to 1750 nm

Wavelength accuracy

  • ±0.02 nm (1520 to 1580 nm, after calibration with build-in reference light source)
  • ±0.04 nm (1580 to 1620 nm, after calibration with build-in reference light source)
  • ±0.3 nm (600 to 1750 nm)

Wavelength linearity

  • ±0.01 nm (1520 to 1580 nm)
  • ±0.02 nm (1580 to 1620 nm)

Wavelength repeatability

  • ±0.003 nm (1 min)

Wavelength resolution

  • Max. resolution: 0.015 nm or better (1520 to 1620 nm, resolution setting: 0.01 nm)
  • 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1.0, 2.0 nm

Resolution accuracy

  • ±5 % (1300 to 1650 nm, resolution: 0.05 nm or more, resolution correction: OFF)

Measurement level range

  • -90 to +20 dBm (1200 to 1650 nm, sensitivity: HIGH3)
  • +80 to +20 dBm (600 to 1200 nm, sensitivity: HIGH3)
  • -60 to +20 dBm (600 to 1000 nm, sensitivity: HIGH3)

Level accuracy

  • ±0.3 dB (1310/1550 nm, input: -30 dBm, sensitivity: HIGH3-1)

Level linearity

  • ±0.05 dB (input: -10 to 30 dBm, sensitivity: HIGH3-1)

Level flatness

  • ±0.1 dB (1520 to 1580 nm), ±0.2 dB (1580 to 1620 nm)

Polarization dependency

  • ±0.05 dB (1550/1600 nm), ±0.05 dB (typ. 1310 nm)

Dynamic range

  • 80 dB (1523 nm, peak ±0.4 nm, resolution: 0.01 nm)
  • 70 dB (1523 nm, peak ±0.4 nm, resolution: 0.1 nm)
  • 45 dB (1523 nm, ave.: 1 s, resolution: 0.1 nm)

Sweep time

  • Approx. 500 ms (Span: 100 nm or less, sensitivity: NORM, HOLD, ave.: 1, 501 samples or less, resolution correction: OFF)
  • Approx. 0.5 s (Span: 100 nm or less, sensitivity: HIGH2, ave.: 1, 501 samples, No signal)

Function

  • Program function (20 program, 200 steps)

Automatic measurement

  • Long-term measurement function

Setting of measuring conditions

  • Scan setting: 0 to 1200 nm
  • Measuring sensitivity setting: NORMAL HOLD/AUTO, MID, HIGH1/2/3
  • Number of averaging setting: 1 to 1000 times
  • Sample number setting: 11 to 20001, AUTO
  • Automatic setting function of measuring conditions
  • Sweep-between-marker function
  • 0 nm sweep function
  • Pulse light measurement function
  • Air/vacuum wavelength measurement function
  • TLS synchronized measurement function

Right Column

Function

Trace display

  • Level scale setting: 0.1 to 10 dB/div, linear
  • Simultaneous display of 3 independent traces
  • Max./Min. hold display
  • Roll averaging display
  • Calculation-between-traces display
  • Normalized display
  • Curve-fit display
  • 3D display
  • Split display
  • Power density display, % display, dB/km display
  • Frequency display of horizontal axis scale

Data analysis

  • WDM waveform analysis (wavelength/level/SNR list display)
  • Optical fiber amplifier analysis (GAIN/NF, Single/Multi channel)
  • PMD analysis, Optical filter analysis, BFL-BLD analysis, FP-LD analysis, LED analysis, SMSR analysis
  • Peak search, bottom search, spectral width search, notch with search
  • Data marker (max. 200), line marker (analysis range specification)
  • Graph display of long-term measurement result

Others

  • Self-wavelength calibration function (using built-in reference light source)
  • Wavelength/Level compensation function, label function, help function

Memory

Built-in FDD

  • 3.5-inch 2HD

Internal memory

  • 32 traces, 20 programs

File format

  • Trace file, program file, measuring condition file, text file (trace, analysis data, etc.), graphics file (BMP,TIFF)

Data output

  • Built-in high speed printer

Interface

  • Remote control: GPIB (2 ports)
  • TLS control interfaces (TTL)
  • Sweep trigger input (TTL)
  • Sample enable input (TTL)
  • Sample trigger input (TTL)
  • Analog output (0 to 5 V)
  • Video output (VGA)

Display

  • 9.4-inch color LCD (Resolution: 640 x 480 dots)

Optical connector

  • FC (Standard)

Power requirement

  • AC 100 to 120/200 to 240 V, 50/60 Hz

Environmental conditions

  • Operating temperature: 5 to 40 °C
  • Storage temperature: -10 to +50 °C
  • Humidity: 80 %RH or less (no condensation)

Dimensions and mass

  • Approx. 425 (W) x 222 (H) x 450 (D) mm, approx. 30 kg

Notes:

  1. Horizontal scale: wavelength display mode
  2. Vertical scale: peak power display mode, resolution: 0.05 nm or more, resolution correction: OFF
  3. At 15 to 30 °C, with 10/125 µm single mode fiber, after 2 hours of warm-up, after optical alignment

Calibration Certificate included!

Get a Quote for Service


Call : 215-485-6313

sales@wyomingelectronics.net

Additional information

Model

MPN

Brand

Product Type

Can’t find what you are looking for?