Expert Technicians
Original Parts
Fast Turn-Arounds
Maintenance Plans
At Wyoming Electronics Inc., we are your go-to experts for specialized repair and maintenance services for the Agilent 86140A Optical Spectrum Analyzer.
Recognized for our technical prowess and rapid response, we ensure that your crucial analytical equipment operates flawlessly, maintaining its precision and reliability for optimal performance.
Expert Repair Solutions for Agilent 86140A:
The Agilent 86140A is a high-performance optical spectrum analyzer designed for rigorous and accurate optical measurements. However, like any sophisticated instrumentation, it may encounter specific operational challenges over time. Here’s how we address these issues:
Common Issues and Our Repair Services:
- System Boot Failures: We resolve continuous reboots and situations where the unit is stuck trying to boot, ensuring a smooth and functional start-up.
- Display Problems: For units with non-functional displays where an external monitor works, we repair or replace the necessary components to restore the primary display functionality.
- Signal Detection Issues: We troubleshoot and fix problems related to no optical signal detection or reading, crucial for the device’s core function.
- Power Button Malfunctions: If the power-on button is stuck or non-functional, we provide quick repairs or replacements to ensure hassle-free operation.
- Calibration Failures: We address both internal and external wavelength calibration failures, ensuring the device meets all calibration standards for accurate measurements.
- Optical Alignment Errors: Our service includes correcting internal optical alignment failures and handling specific auto-alignment issues, such as monochromator errors, to maintain measurement accuracy.
- Mechanical and System Errors: We resolve error codes such as “20002: Error detected in slit positioning system 0333,” which involves repairs to the motor controlling the resolution bandwidth slit wheel.
- Optical Power and Wavelength Accuracy: If optical power readings are low or if there are issues with wavelength accuracy or linearity, our technicians adjust and calibrate the system for precise functionality.
- Grating Errors: We troubleshoot and correct grating errors following auto-alignment or measurement processes, ensuring the integrity of the spectral analysis.
Why Choose Wyoming Electronics Inc. for Your Agilent 86140A Repairs?
- Specialized Expertise: Our technicians have extensive experience and training specifically with Agilent optical spectrum analyzers, ensuring high-quality service.
- Advanced Diagnostic Equipment: We utilize the latest in diagnostic tools and technology to accurately identify issues and implement the most effective repairs.
- Fast Turnaround Time: We understand the importance of minimizing downtime in analytical environments and strive to complete repairs quickly and efficiently.
- Transparent Pricing: Our maximum service charge is $6500, but each client receives a tailored quote after a thorough evaluation, ensuring you pay only for necessary services without any hidden costs.
- Commitment to Quality: We use only genuine Agilent parts and components for replacements to ensure your equipment performs as expected after repairs.
Steps to getting your 86140A fixed:
1) Fill our RMA form here, and ship us your defective 86140A
2) We will perform free evaluation and quote you with lead time
3) You will accept or decline the repair
4) We will repair and or return your 86140A
Specifications:
Wavelength Specifications
- Range: 600 nm to 1700 nm
- Reproducibility: ± 0.002 nm (With applied input fiber 9/125 ?m; ? 1 min)
- Span range: 0.2 nm to full range and zero span
Accuracy after calibration with internal source and with enhanced wavelength calibration for specified range
- 1480 to 1570 nm: Typical ± 0.01 nm
- 1570 to 1620 nm: Typical ± 0.025 nm
- Conditions: At room temp; with applied input fiber 9/125 ?m
After calibration with external reference source(s)
- ± 10 nm of calibration reference point(s): Typical ± 0.01 nm
- Conditions: At room temp; with applied input fiber 9/125 ?m
- After user calibration over full wavelength range (600 to 1700 nm): ± 0.2 nm
- Conditions: T (20 to 30 °C); with applied input fiber 9/125 ?m
Absolute accuracy
- Typical: ± 0.5 nm
- Conditions: Factory calibration 2 year cycle; T (20 to 30 °C); with applied input fiber 9/125 ?m
- Tuning repeatability: ± 0.002 nm
- Conditions: With applied input fiber 9/125 ?m; ? 1 min
Span linearity
- 1525 to 1570 nm: Typical ± 0.01 nm
- For spans < 40 nm: Typical ± 0.02 nm
- Conditions: T (20 to 30 °C); with applied input fiber 9/125 ?m
Amplitude Specifications
Sensitivity
- Sensitivity is defined as signal value > 6 x RMS noise value
- 600 to 750 nm, 750 to 900 nm: -60 dBm, -75 dBm (T (0 to 30 °C), 2nd order)
- 900 to 1250 nm, 1250 to 1610 nm: -75 dBm, -90 dBm (T (0 to 30 °C))
- 1610 to 1700 nm: -80 dBm (T (20 to 30 °C))
Maximum Measurement Power
- Resolution bandwidth setting < channel spacing
- 1525 to 1700 nm: Typical +15 dBm per channel, +30 dBm total
- 600 to 1000 nm: Typical +15 dBm per channel, +30 dBm total
- 1000 to 1525 nm: Typical +12 dBm per channel, +30 dBm total
Maximum Safe Power
- Total safe power: +30 dBm
- Total power within any 10 nm portion of the spectrum: +23 dBm
Absolute Accuracy
- At -20 dBm, 1310 nm/1550 nm: ± 0.5 dB
- For resolution ? 0.1 nm, with applied input fiber 9/125 ?m
Scale Fidelity
- Autorange off: ± 0.05 dB (Excluding amplitude errors at low power levels due to noise, T (20 to 30 °C), with applied input fiber 9/125 ?m)
- Autorange on: ± 0.07 dB
- Display scale (log scale): 0.01-20 dB/DIV, -120 to +90 dBm
Amplitude Stability (1310 nm, 1550 nm)
- 1 minute: ± 0.01 dB (For signals within 8 dB of top of screen, with applied input fiber 9/125 ?m)
- 15 minutes: Typical ± 0.02 dB (With applied input fiber 9/125 ?m)
- Flatness: With applied input fiber 9/125 ?m
Specific Flatness Values
- 1290 to 1330 nm: ± 0.2 dB
- 1525 to 1570 nm: ± 0.2 dB
- 1525 to 1610 nm: ± 0.7 dB (Absorption of light by atmospheric moisture affects flatness at 1350 to 1420 nm)
Calibration Certificate included!
Get a Quote for Service
Call : 215-485-6313
sales@wyomingelectronics.net
Additional information
Brand | |
---|---|
Model | |
Analyzer Type | |
Wavelength Range | |
Absolute Wavelength Accuracy | ±0.5nm |
MPN | |
Product Type |