At Wyoming Electronics Inc, we specialize in the repair and service of the Tektronix TDS8000B Digital Sampling Oscilloscope. Our experienced team of technicians is dedicated to providing top-notch service and ensuring that your oscilloscope operates at its peak performance.

When you choose us for the repair and service of your Tektronix TDS8000B oscilloscope, here is an overview of how we handle the process:

  1. Initial Assessment: Upon receiving your oscilloscope, our technicians conduct a comprehensive assessment to evaluate its condition. We inspect the exterior for any physical damage, examine the connectors and cables for proper connections, and assess the overall functionality of the instrument.
  2. Troubleshooting and Diagnostics: If your oscilloscope is experiencing issues or malfunctions, our skilled technicians employ advanced troubleshooting techniques to identify the root cause of the problem. We utilize specialized equipment, follow Tektronix’s recommended procedures, and draw upon our expertise to diagnose and isolate the faulty components or subsystems.
  3. Component Replacement: Once the problematic components are identified, we proceed to replace them with genuine Tektronix parts. We source these components from authorized suppliers to ensure compatibility, reliability, and adherence to the original specifications of your oscilloscope.
  4. Calibration and Adjustment: Following the component replacement, we meticulously calibrate and adjust your Tektronix TDS8000B oscilloscope. Our technicians utilize precision test equipment and software tools to align the instrument’s measurements and readings with known reference signals. This step guarantees accurate and reliable performance.
  5. Firmware and Software Updates: As part of our comprehensive service, we check for any available firmware and software updates provided by Tektronix. If applicable, we update the oscilloscope’s firmware to the latest version to leverage enhanced features, improved stability, and bug fixes.
  6. Rigorous Testing: Before returning your oscilloscope, we subject it to rigorous testing procedures. Our technicians verify the accuracy of measurements across different signal frequencies, assess the functionality of all features and controls, and ensure that the instrument operates within specified tolerances.
  7. Thorough Cleaning and Maintenance: We understand the importance of a clean and well-maintained instrument. As a final step, we thoroughly clean your Tektronix TDS8000B oscilloscope to remove any dust, debris, or contaminants that may have accumulated. This cleaning process not only improves the appearance but also helps prolong the lifespan of your instrument.
  8. Detailed Service Report: Along with your repaired oscilloscope, we provide a detailed service report. This report outlines the repairs performed, components replaced, calibration results, and any additional observations or recommendations made during the service process. It serves as a valuable reference and documentation for your records.

At Wyoming Electronics Inc, we are committed to delivering exceptional repair and service solutions for the Tektronix TDS8000B Digital Sampling Oscilloscope. With our technical expertise, attention to detail, and adherence to Tektronix’s guidelines, you can trust us to keep your instrument in optimal working condition.

Features & Advantages

Bandwidth from DC to over 70 GHz
Enjoy broad bandwidth capabilities, extendable beyond 70 GHz as higher speed modules become available, accommodating future advancements in technology.

Superior Trigger Jitter and Horizontal Timebase Stability
Achieve exceptional precision and stability in timing measurements, essential for high accuracy in demanding applications.

Modular Design
Adapt the oscilloscope to your specific needs with a wide range of electrical and optical plug-in modules, ensuring flexibility for both current and future applications.

Multi-Channel Acquisition Capability
Simultaneously acquire up to eight channels, enhancing the efficiency and breadth of your data collection.

High Resolution and Repeatability in Measurements
Depend on excellent measurement fidelity and repeatability, crucial for consistent testing outcomes.

Comprehensive, Accurate Automatic Measurement System
Leverage a fully automated system that delivers precise and reliable measurements every time.

User-Friendly Interface
Navigate easily with an intuitive user interface and a large 10.4-inch display, featuring a Microsoft Windows-based graphical user interface for enhanced interaction.

Enhanced Network Security with Windows 2000
Benefit from improved network security, ensuring safe and secure data handling.

Applications

Semiconductor Testing: Tailor-made for detailed analysis in semiconductor applications.
Impedance and Crosstalk Characterization: Utilize TDR for in-depth impedance and crosstalk studies.
High-Speed Digital Data Communications: Ideal for the examination of high-speed digital signals.
TDS8000B Digital Sampling Oscilloscope Overview

The TDS8000B offers unparalleled onboard measurement and waveform-processing capabilities among ultra-high bandwidth oscilloscopes. Known for its outstanding measurement repeatability, exceptional vertical resolution, and rapid waveform acquisition and display update rates, the TDS8000B excels in semiconductor testing, TDR characterization of circuit boards, IC packages, cables, and high-speed digital communications.

Advanced Waveform Acquisition
The state-of-the-art timebase of the TDS8000 Series enables time sweep speeds from 1.0 ps/div to 5 ms/div with record lengths ranging from 20 to 4000 points and a sample interval down to 10 femtoseconds (0.01 ps). Additionally, the timebases of the 8000 Series Oscilloscopes can be synchronized with a 10 MHz reference, providing enhanced long-term stability and the ability to synchronize multiple TDS8000Bs with other testing equipment and devices under test.

Enhanced Viewing and Sampling Rates
The TDS8000B features two magnification windows for high-resolution re-acquisition of waveform sections, and boasts the highest sample rate among sampling oscilloscopes. Its multi-processor architecture with dedicated digital signal processors per channel ensures top waveform acquisition rates.

Unmatched TDR Performance
With the 80E04 TDR Sampling Module, the TDS8000B delivers unparalleled TDR functionality on up to eight channels simultaneously, featuring independently adjustable polarity step-generators for each channel, providing the only true differential TDR system available today.

Robust Platform and Connectivity
Built on Tektronix’s robust sampling oscilloscope platform, the TDS8000B integrates MS Windows-based PC technologies with advanced waveform acquisition technology. It includes a variety of interfaces and mass storage options, along with a large, full-color display for detailed waveform analysis. The system’s open Windows environment allows for sophisticated data analysis using commercially available software, and with TekVISA™, it can be controlled by software applications running either on the instrument or on network-connected external PCs.

Shipping & Handling


We offer fast domestic and international shipping. We can ship on your FedEx, UPS, or DHL account upon request.  Lead time is typically 1-3 business days. Overseas customers, please consider duty’s and taxes before purchasing

Payments


We accept PayPal, Credit Cards, Wire Transfers, Checks, and NET Terms (select and approved customers only).

Acquisition Modes – Sample (normal), envelope and average.

Number of Sampling Modules Accommodated – Up to four, dual-channel electrical and two, single-channel optical sampling modules.

Number of Simultaneously Acquired Inputs – Eight channels maximum (eight electrical or two optical and six electrical).

Vertical Systems

Rise Time/Bandwidth – Determined by the sampling modules used.

Vertical Resolution – 14 bits over the sampling modules’ dynamic range.

Horizontal System

Main and Magnification View Timebases – 1 ps/div to 5 ms/div in 1-2-5 sequence or 1 ps increments.

Maximum Trigger Rate – 200 kHz.

Typical Acquisition Rate – 150 Ksamples/sec. per channel.

Time Interval Accuracy –

Horizontal scale <21 ps/div: 1 ps + 1% of interval.

Horizontal scale ?21 ps/div:

8 ps +0.1% of interval (short-term optimized mode).

8 ps + 0.01% of interval (locked to 10 MHz mode).

Horizontal Deskew Range: -500 ps to +100 ns on any individual channel in 1 ps increments.

Record Length – 20, 50, 100, 250, 500, 1000, 2000 or 4000 samples.

Calibration Certificate included!