Multi
Mobile Homepage logo

Repair and Service of Tektronix DSA8300 Digital Serial Analyzer

Expert Technicians

Original Parts

Fast Turn-Arounds

Maintenance Plans

At Wyoming Electronics Inc, we specialize in the repair and service of the Tektronix DSA8300 Digital Sampling Oscilloscope. Our team of highly skilled technicians is dedicated to providing reliable solutions and ensuring the optimal performance of this advanced instrument.

When you choose us for the repair and service of your Tektronix DSA8300 oscilloscope, here is an overview of our process:

  1. Initial Assessment: Upon receiving your oscilloscope, our technicians conduct a thorough initial assessment. We carefully inspect the physical condition of the instrument, checking for any visible damage or signs of wear. We also evaluate the overall functionality, examining connectors, buttons, and displays.
  2. Troubleshooting and Diagnostics: If your oscilloscope is experiencing any operational issues, our technicians employ advanced troubleshooting techniques. Utilizing specialized equipment and following Tektronix’s recommended procedures, we systematically identify and diagnose the root causes of the problems.
  3. Component Replacement: Once the faulty components or subsystems are identified, we proceed with component replacement. We use genuine Tektronix parts sourced from authorized suppliers to ensure compatibility and maintain the instrument’s original performance specifications. Our technicians are experienced in handling delicate electronic components, ensuring precise and accurate replacements.
  4. Calibration and Adjustment: After replacing the faulty components, we perform calibration and adjustment procedures. Using precision test equipment and software tools, we align the measurements and readings of your Tektronix DSA8300 oscilloscope with known reference signals. This step ensures accurate and reliable performance.
  5. Firmware and Software Updates: As part of our comprehensive service, we check for available firmware and software updates provided by Tektronix. If applicable, we update the oscilloscope’s firmware to the latest version, incorporating any enhancements, bug fixes, and stability improvements provided by the manufacturer.
  6. Rigorous Testing: Before returning the oscilloscope to you, we subject it to rigorous testing procedures. Our technicians verify the accuracy of measurements across various signal frequencies, thoroughly test all features and controls, and ensure that the instrument meets specified tolerances.
  7. Cleaning and Maintenance: We understand the importance of a clean and well-maintained instrument. As a final step, we meticulously clean your Tektronix DSA8300 oscilloscope, removing dust, debris, and contaminants that may have accumulated during usage. This cleaning process helps improve the longevity and performance of your instrument.
  8. Detailed Service Report: Along with your repaired oscilloscope, we provide a detailed service report. This report outlines the repairs performed, components replaced, calibration results, and any additional observations or recommendations made during the service process. It serves as a valuable reference and documentation for your records.

At Wyoming Electronics Inc, we are committed to providing exceptional repair and service solutions for the Tektronix DSA8300 Digital Sampling Oscilloscope. With our expertise, attention to detail, and adherence to Tektronix’s guidelines, you can trust us to restore your instrument to its optimal working condition.

Steps to getting your DSA8300 fixed:
1) Fill our RMA form here, and ship us your defective DSA8300
2) We will perform free evaluation and quote you with lead time
3) You will accept or decline the repair
4) We will repair and or return your DSA8300

Key features

The DSA8300 is a state-of-the-art equivalent time sampling oscilloscope that provides the highest fidelity measurement and analysis capabilities for communications signal analysis, serial data network analysis, and serial data link analysis applications.? Best vertical resolution (16 bit A/D):
? Electrical resolution: <20 ?V LSB (for 1 V full range)
? Optical resolution depends on the dynamic range of the optical module ranges from <20 nW for the 80C07B (1 mW full range) to <0.6 ?W for the 80C10B (30 mW full range)
? The DSA8300 supports up to 8 simultaneously acquired signals
? A wide variety of optical, electrical, and accessory modules to support your specific testing requirements
? Use the new Change/View Module Config function to install or remove modules without powering down the instrument
? Fully integrated optical modules that support all standard optical data rates from 155 Mb/s to 100 Gb/s
? Certified optical reference receivers support specified requirements for standards-mandated compliance testing
? High optical sensitivity and low noise as well as the wide dynamic range of the optical sampling modules allows accurate testing and characterization of short-reach to long-haul optical communications standards
? Fully calibrated clock recovery solutions; no need to manually calibrate for data pick-off losses
? Calibrated extinction ratio measurements ensure repeatability of extinction ratio measurements to <0.5 dB among systems with modules with this factory calibration option
? Selectable bandwidths (module 80E07B, 80E08B, 80E09B, 80E10B, 80E11, 80E11X1) allow the user to trade-off sampler bandwidth and noise for optimal data acquisition performance
? Remote samplers (module 80E07B, 80E08B, 80E09B, 80E10B, 80E11, 80E11X1) or compact sampling extender module cables support minimal signal degradation by locating the sampler in close proximity to the device under test
? World’s highest-performance integrated TDR (10 ps typical step rise time) supports exceptional impedance discontinuity characterization and high dynamic range for S-parameter measurements to 50 GHz.
? Complete suite of over 120 automated measurements for NRZ, RZ, and Pulse signal types
? Automated mask testing with over 80 industry-standard masks. New masks can be imported into the DSA8300 to support new emerging standards. In addition, users can define their own masks for automated mask testing
? Vertical and Horizontal histograms for statistical analysis of acquired waveforms
? Vertical, Horizontal, and Waveform cursors (with measurements)
? Jitter, Noise, BER, and Serial Data Link Analysis is provided through the 80SJNB Basic and Advanced software application options
? Advanced TDR Analysis, S-parameter measurements, Simulation Model Extraction, and Serial Link Simulation capabilities are provided through the IConnect® Software application options
? Efficient Programmatic Interface (IEEE-488, Ethernet, or local processor access) enable High Test Throughput.

Our expert solutions are designed to ensure your DSA8300 operates at peak performance with the highest fidelity signal capture and analysis capabilities.

Comprehensive Support and Calibration Services Include:
  1. Signal Capture and Fidelity Assurance:
    • We provide detailed calibration services targeting the oscilloscope’s ability to capture signals with exceptionally low time-base jitter and superior vertical resolution. Our calibration process ensures your device maintains its 425 fs typical jitter on up to 8 channels and less than 100 fs on up to 6 channels using the 82A04B phase reference module.
  2. Module Installation and Configuration Flexibility:
    • The DSA8300 supports a diverse array of optical and electrical modules. We assist in configuring these modules to your specific testing needs and ensure that module installation or removal can be done without powering down the instrument, as facilitated by the DSA8300’s Change/View Module Config function.
  3. Optical Module Calibration and Testing:
    • Our service includes calibration of integrated optical modules that support data rates from 155 Mb/s to 100 Gb/s and optical bandwidths exceeding 80 GHz. We ensure that these modules meet the standards-mandated compliance testing requirements and maintain high optical sensitivity and dynamic range for accurate characterization of optical communications standards.
  4. Electrical Module Optimization:
    • We calibrate and optimize electrical modules that feature bandwidths up to 70 GHz. Our service includes adjusting the selectable bandwidth settings to balance sampler bandwidth and noise, enhancing data acquisition performance. Remote sampler and compact sampling extender modules are also supported to minimize signal degradation.
  5. Advanced Analysis Capabilities:
    • Our technicians ensure that the DSA8300’s suite of automated measurements and mask testing capabilities are fully functional. This includes over 120 automated measurements for NRZ, RZ, and Pulse signal types, and support for over 80 industry-standard masks as well as user-defined masks.
  6. Performance and Throughput Enhancement:
    • We work to maximize the high sample acquisition rate of up to 300 kS/s per channel. Our services also streamline the oscilloscope’s programmatic interface for high test throughput, utilizing IEEE-488, Ethernet, or local processor access.
  7. Specialized Software Application Support:
    • Support is available for advanced software applications such as the 80SJNB for jitter, noise, and BER analysis, and the IConnect® Software for TDR analysis, S-parameter measurements, simulation model extraction, and serial link simulation. We ensure these applications are correctly integrated and functioning to their full potential.
  • Optical bandwidths to >80 GHz
  • Electrical bandwidths to >70 GHz
  • Very low-noise electrical samplers (280 ?V at 20 GHz, 450 ?V at 60 GHz, typical)
  • High Sample Acquisition Rate up to 300 kS/s per channel
  • 425 fs typical on up to 8 simultaneously acquired channels
  •  <100 fs typical on up to 6 channels with 82A04B phase reference module

 

Calibration Certificate included!

Get a Quote for Service


Call : 215-485-6313

sales@wyomingelectronics.net

Additional information

MPN

Brand

Trademark

Type

Can’t find what you are looking for?